5.2.1 Overview of possible administration jobs by types of administration
Master media RF-Stick Wireless online network V NET
Opening duration
Release and block mode
Time profiles
Events
Validation (only V-NET)
Validity
Office-function
5.2.2 Opening duration
The opening duration is the length of time during which the locking device remains coupled, after
an authorised locking media was held in the reading field of the locking device.
The longer the opening duration, the more time people have to operate the locking device after
the authenticating with a locking media. The maximum opening duration is 180 seconds.
The opening duration can be set via master media (see "Setting opening period" on page121) and
via CEStronics SuiteA detailed manual is available in the OMEGA Suite Help.
5.2.3 Release and block mode
A locking device which is in release mode remains permanently coupled, i.e. the door can be
opened permanently without necessitating the use of any locking media.
A locking device in block mode remains permanently uncoupled, i.e. the door cannot be opened.
An access even with an authorised locking media is no more possible.
Details on this and further opening modes can be found under "Opening mode of the locking
devices" on page83.
The release and block mode is set via master media (see "Activating release mode" on page122
and "Activating block mode" on page124).
5.2.4 Time profiles
This function requires the use of the OMEGA Suite software.
There are three types of time profiles: