27
APPENDIX B: 1-Point to 2-Point Electrical Connection Conversion, Kit P/N 901168
WARNING:
Disconnect all power to the dishwasher before working on the machine.
DH6000 Series 1-Point to 2-Point Electrical Connection
Conversion Kit, P/N 901168
KIT PARTS:
(1) P/N 111833, Input Terminal Block
(1) P/N 336386, Bracket, Incoming Electrical
(2) P/N 107136, Screw, 10-23 x 3/8" Hex Hd.,
(2) P/N 107966, Grip Nut, w/nylon Insert,
(4) P/N 100007, Screw, 10-32 x 3/8" Truss Hd.,
(1) P/N 116045, Matrix Label, 2-Point Electrical
Data Plate, (Printed in-house)
(1) P/N 117097, Instruction Sheet,
SPECIAL TOOL: 1/4" DRILL BIT
(not included in kit)
1. Disconnect power to the dishwasher and remove the front panels.
2. Locate MACHINE input terminal block on right front corner of machine base (Fig. 2).
3. Identify the booster wires L1, L2, and L3.
4. Disconnect the wires. Note: L1 is on top of the block, L3 on bottom.
5. Install the kit terminal block to the bracket using (4) 10-32 truss head screws (Fig. 3).
Fig. 1
Fig. 2
Fig. 3
MACHINE TERMINAL BLOCK
BOOSTER TERMINAL BLOCK