NVF5 Series User Manual Appendix B Parameter list
Code
Name
Setting Range
Default
Change
F0 Basic Program Group
F0.00 Motor Control Mode
0Sensorless Vector Control
1Reserve
2V/F Mode
2
F0.01 Command Source
0Integral Keypad
1Digital Terminal
2Communication
3Remote Panel
0
F0.02
Main Frequency
Reference
0Digital Given
1AI1
2AI2
3Reserve
4 High Speed Pulse HDI
Reference
5Preset Speed Reference
6Simple PLC Reference
7Close Loop PID Reference
8Reserve
9Potentiometer Reference
0
F0.03
Auxiliary Frequency
Source Option
Same as F0.02Main Frequency
Reference
0
F0.04
Main Aux. Frequency
Source Computing
Ones PlaceFrequency Source
Selection
0Main Frequency Ref.
1Computing Result
Tens Place
Main Aux.
Frequency Source Computing
0Main + Aux.
1MianAux.
2MAX(the bigger one of
both)
3
MIN(the smaller one of
both)
0x0000
F0.05 Digital Given
F0.09 F0.08
5.00Hz
F0.06 Direction Setting
0Default Direction
1Reverse Enable
2Reverse Disable
0
F0.07
Max. Output
Frequency
F0.08 600.00Hz
50.00 Hz
F0.08 Maximum Frequency
F0.09 F0.07
50.00 Hz
- 112 -

Table of Contents

Other manuals for CHINT NVF5 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CHINT NVF5 Series and is the answer not in the manual?

CHINT NVF5 Series Specifications

General IconGeneral
BrandCHINT
ModelNVF5 Series
CategoryInverter
LanguageEnglish

Related product manuals