NVF5 Series User Manual Appendix B Parameter list
Fd .03
Setting(After
(0.00 ~ 600.00)Hz
0.00Hz
●
Fd .04 Torque Reference
(-300.0 ~ +300.0)%(Motor
Rated Torque)
0.0%
●
Fd .05 Output Frequency
(0.00 ~ +600.00)Hz
0.00Hz
Fd .06 Output Voltage
(0 ~ 480)V
0V
Fd .07 Output Current
( 0.0 ~ 3000.0 ) A
(Corresponding 0.0~3.0)Ie)
0.0A
●
Fd .08 Running RPM
(0 ~ 60000)rpm
0rpm
Fd .09 Output Torque
(-300.0 ~ +300.0)%(Motor
Rated Torque)
0.0%
●
Fd .10 ASR Controller Output
(-300.0 ~ +300.0)%(Motor
Rated Torque)
0.0%
●
Fd .11 Torque Current
(-300.0 ~ +300.0)%
0.0%
Fd.12 Flux Current
(0 ~ 100.0)%
0.0%
Fd .13 Motor Power
(0.0 ~ 200.0)%(Motor Rated
Power)
0.0%
●
Fd .14
(-300.00 ~ +300.00)Hz
0.00Hz
●
Fd .15
(-300.00 ~ +300.00)Hz
0.00Hz
●
Fd .16 DC Bus Voltage
(0 ~ 800)V
0
Fd .17 Inverter Status
Bit0:Run/Stop
Bit1:Reverse/Forward
Bit2:Zero Speed Running
Bit3:Accelerating
Bit4:Decelerating
Bit5:Constant Speed Running
Bit6:Pre-flux
Bit7:Auto Tuning
Bit8:Overcurrent Stall
Bit9:DC Overvoltage Stall
Bit10:Torque Limit
Bit11:Frequency Limit
Bit12:Fault
Bit13:Ready
Bit14:Reserve
Bit15:UnderVoltage/Normal
0x0000
●
- 134 -