Cisco 10000 Series Router Troubleshooting Guide
OL-0439-02
Chapter 1 Basic Troubleshooting Tasks and Startup Issues
Displaying Cisco IOS Software Version and System Environment Information
In the following sample of output from the show version command, some of the information that may
be useful for troubleshooting appears in bold type:
Router# show version
Cisco Internetwork Operating System Software
IOS (tm) 10K Software (C10K-EBOOT-M), Experimental Version 12.0(19990916:085921)
[BLD-omega_isp.ios-weekly 101]
Copyright (c) 1986-1999 by Cisco Systems, Inc.
Compiled Thu 16-Sep-99 05:20 by
Image text-base: 0x60008900, data-base: 0x6047A000
ROM: System Bootstrap, Version 12.0(19990719:134935) [fyang-cre1 1004], DEVELOPM
ENT SOFTWARE
another-omega uptime is 6 hours, 7 minutes
System returned to ROM by power-on at 14:12:52 EST Fri Jan 7 2000
System image file is "bootflash:c10k-eboot-mz"
cisco C10000 (CRE-RP) processor with 114688K/16384K bytes of memory.
Processor board ID noserial
R7000 CPU at 262Mhz, Implementation 39, Rev 1.0, 256KB L2, 2048KB L3 Cache
Unknown midplane, Version 0.0
Last reset from register reset
1 Ethernet/IEEE 802.3 interface(s)
1 FastEthernet/IEEE 802.3 interface(s)
509K bytes of non-volatile configuration memory.
20480K bytes of Flash PCMCIA card at slot 0 (Sector size 128KB).
Configuration register is 0x0
Using the show environment Command for Basic Troubleshooting
Use the show environment command to
Make sure the system operating temperature is equal to or less than 40 degrees C or 104 degrees F
at the inlet.
Report the operational status of the PEMs and blower
If the operating temperature is not between 41 degrees F and 104 degrees F, refer to the “Blower Module
Faults” section on page 2-5.
The following example is sample output from the show environment command:
Router# show environment
Temperature normal:chassis inlet measured at 29C/84F
Temperature normal:chassis core measured at 39C/102F
Fan: OK
Power Entry Module 0 type DC status: OK
Power Entry Module 1 type AC status: Failure
The Cisco 10000 series router default temperature alarm thresholds are programmed to assert at
approximately these conditions:
Minor inlet and core alarms will assert when the ambient temperature is within a few degrees of 40
degrees C.
Major inlet and core alarms will assert when the ambient temperature is within a few degrees of 50
degrees C.
Critical inlet and core alarms will assert when the ambient temperature is within a few degrees of
70 degrees C.

Table of Contents

Other manuals for Cisco 10000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco 10000 Series and is the answer not in the manual?

Cisco 10000 Series Specifications

General IconGeneral
BrandCisco
Model10000 Series
CategoryNetwork Router
LanguageEnglish

Related product manuals