EasyManuals Logo

Cisco Catalyst 9300X User Manual

Cisco Catalyst 9300X
140 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #109 background imageLoading...
Page #109 background image
CHAPTER 6
Installing a Fan Module
Fan Modules Overview , on page 97
Installation Guidelines, on page 98
Installing a Fan Module, on page 98
Finding the Fan Module Serial Number, on page 99
Fan Modules Overview
All the switches except C9300LM-48T-4Y have three internal hot-swappable fans. A powered switch should
always have more than one operational fan. The switch can operate with two operational fans and one
nonfunctional fan, but the failed fan should be replaced as soon as possible to avoid a service interruption due
to a second fan fault. A switch with one or more fans failed or removed will operate with fans at a faster speed,
producing increased sound.
Sharp edges on the fan module can cause serious injury. Keep fingers clear.
Danger
Figure 59: Fan Module
Retainer clip3Fan LED1
Cisco Catalyst 9300 Series Switches Hardware Installation Guide
97

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 9300X and is the answer not in the manual?

Cisco Catalyst 9300X Specifications

General IconGeneral
CategorySwitch
Total number of MAC addresses64, 000
Total number of IPv4 routes32, 000
Total number of IPv6 routes16, 000
Jumbo frames9198 bytes
DRAM8 GB
Flash16 GB
ModelCisco Catalyst 9300X
Number of VLANs4, 094
Operating Temperature32°F to 104°F (0°C to 40°C)
Operating Humidity5 to 90% relative humidity

Related product manuals