Cisco SCE8000 GBE Installation and Configuration Guide
Appendix C Cisco Service Control Engine System Log Messages
Informational Messages, Severity Level 6
Error Message %LOCAL7-6-ACTIVATE_FC: "Flow data-base (FC) activated. Containing %d
flows"
Explanation
This message indicates that the flow context database is activated for
RUC_MaxFlowContexts flows.
Recommended Action None.
Error Message %LOCAL7-6-SET_CONFIG: "Set connection-mode: connection mode is: %s,
box priority is: %s, fail-over mode is: %s, physically-connected link group is: %lu
Explanation
This message indicates the redundancy connection mode set on the SCE, and other
details, such as box priorities, the failover mode, and the physically connected link group.
Recommended Action None.
Error Message %LOCAL7-6-STATE_TRANSITION: "state changed from <%s> to <%s>."
Explanation
This message is generated when there is a change in the state of the Cisco SCE cascade
topology from the present state.
Recommended Action None.
Error Message %LOCAL7-6-USER_FAILOVER: "Redundancy: User failover = %d."
Explanation
This message indicates whether a user has requested for the failover or not. 0 indicates
false and 1 indicates true.
Recommended Action None.
Error Message %LOCAL7-6-SM_CONNECTION_STATUS_CHANGE: "Redundancy: SM connection
status changed from %s to %s."
Explanation
This message is displayed to indicate that the Subscriber Manager connection state has
changed and consequently, the log information state has also changed.
Recommended Action None.
Error Message %LOCAL7-6-SM_FAILOVER: "Redundancy: SM connection status is down while
up in peer box."
Explanation
This message is displayed to indicate that the Subscriber Manager connection is down
due to a session timeout. The connection status is verified in the cascade connection when the
present Cisco SCE platform does not have the Subscriber Manager connection and tries to activate
another Cisco SCE platform connection.
Recommended Action None.