Disassembly, Reassembly and Lubrication
CL-S6621 3-16
When once the “Unit, Mechanism” was removed (Paper path adjustment):
When once the “Unit, Mechanism” was removed in “
3-6-13(1) Unit, Mechanism”, you need
to perform the following paper path adjustment after reassembling the “Case U” Block.
NOTE: If you haven’t removed the “Unit, Mechanism”, you don’t need to perform this
adjustment.
This procedure is to align the position of the “Unit, Mechanism” with the “Case U” Block. So,
you need to shift the “Unit, Mechanism” a little after loosening its screws
.
1) Before starting, be sure that the “Case U” Block is already assembled in the printer.
2) Loosen (do not remove) 8 screws that fasten the “Unit, Mechanism” to the printer.
3) Open the “SA, Head” Block.
4) Open the “Unit, Sensor U”.
5) Set a ruler along the 5 places (2 places (,) of the “Unit, Mechanism” and 3 places
(,,) of the “Case U” Block.
6) Move the “Unit, Mechanism” so that 5 places are aligned in line.
7) Close the “Unit, Sensor U” and “SA, Head” Block, and then fasten the 8 screws to fix
the “Unit, Mechanism”.
"SA, Head" Block
Unit, Sensor U
8 screws