3-6. Adjustments
3-6. Adjustments
CLP-621 & CLP-631 3-40
3-6-1. Transparent/Reflective Sensor Position Adjustment
When you replace one of the following parts, perform both sensor position adjustment and sensor
sensitivity adjustment.
Main PCB Unit
Transparent Sensor PCB SA
Reflective Sensor PCB SA
(1) Sensor position adjustment (factory mode)
After entering Factory mode, adjust the following submenu items:
Through Sensor Position
Reflect Sensor Position
For details, refer to 2-3-2-(3-3)-(a) “Factory mode menu table”.
(2) Sensor sensitivity adjustment (maintenance mode)
In this adjustment, since the printer has not a display, PC is used instead.
All operations will be done with the keys on the printer’s control panel.
Communication between the printer and a PC is made through the serial port.
(2-1) Preparation
Before starting adjustment, prepare the following items:
Media (both label paper and tag) (recommended media or media you use)
RS-232C serial cable
PC which is installed Terminal software such as HyperTerminal and TeraTerm.
Windows normally comes with the HyperTerminal. If the software is not installed, you
need to install it.
* Windows® is a registered trademark of Microsoft Corporation in the United States
and/or other countries.
Setting on the PC side:
Make the following settings on the PC beforehand:
1. Connect the RS-232C serial cable between the printer and the PC.
2. On the PC, start the Terminal software.
3 Set the transmission conditions on the Terminal software so that they are identical to
those on the printer side.
Default values of the printer:
• Transmission speed (baud rate): 9,600 bps
• Data length: 8 bits
• Stop bit: 1 bit
• Protocol: XON/XOFF