2-3. Operation Panel
CLP-621 & CLP-631 2-46
How to change the value in the Factory Mode menu
For example, the following shows how to logically move the thermal head position 1 mm
(0.04”) to the right. In this case, you should add 8 (dots) to the current value (e.g. +08).
• Variable range: -16 to +32 dots (default +08 dots) (-2 to +4 mm, -0.08 to +0.16 mm”)
• 8 dots correspond to 1 mm. (203 dots correspond to 1”.)
1. Perform steps 1 to 6 on page 2-42 to enter the Factory Mode menu. See (b) “How to
enter
the Factory/Service Mode”.
2. Press the [PAUSE] key until “Mach Hor Pos” submenu is printed.
Note: In the actual printing, the cursor “^” will be printed instead of “
(underline)”.
3. To set the value to 16 (8 plus 8), press the [FEED] key to move the cursor to the next
digit (+08), and then press the [STOP] key once to specify “1”.
Each time you press the key, the value of the current digit with the cursor will scroll (0,
1, 2, 3, 4, ...., 9, 0).
4. Next, press the [FEED] key to move the cursor to the next digit (+18).
The changed value is printed.
5. Press the [STOP] key 8 times to specify “6”.
Each time you press the key, the value will scroll (8, 9, 0, 1, ...., 6).
6. To save the set value, press the [PAUSE] key.
The set value will be printed. Be sure that the new value is “16”, and then press the
[MODE] key to exit the item.
* If the value is not the one you expected, repeat above operation.
Do you want to change “Factory Mode Menu” items?
Y
es=(PAUSE) No=(STOP) Exit=(MODE)
Through Sensor Position +000
Save=(PAUSE) Next Digit=(FEED) Change value=(STOP) Exit=(MODE)
:
:
Mach Hor Pos +08
Save=(PAUSE) Next Digit=(FEED) Change value=(STOP) Exit=(MODE)
Mach Hor Pos +18
Save=(PAUSE) Next Digit=(FEED) Change value=(STOP) Exit=(MODE)
Mach Hor Pos +16
Save=(PAUSE) Next Digit=(FEED) Change value=(STOP) Exit=(MODE)
1 mm
+