2 – 9
(4) PARAMETER DISPLAY?
This mode confirms the basic control parameters of equipment as well as
input and output of each part.
If pressing the Enter key at (PARAMETER DISPLAY?), it moves to the lower
mode. Then, whenever press the mode switch it moves as follows: (SENSOR
INPUTS [ENTER]) ® (DIGITAL INPUTS [ENTER]) ® (CONTRACTOR
REQUESTS [ENTER]) ® (SYSTEM PARAMETERS [ENTER]) ® (EXIT
[ENTER])
To move the lower mode in each mode, press the ENTER key.
1 SENSOR INPUTS: It shows the ADC input values.
1. BATTERY VOLTAGE: It shows to the battery voltage.
2. DRIVE SENSOR INPUTS: It shows the input value of driving ADC. (It
contains lower modes)
i. DRIVE VOLTAGE : It indicates the driving voltage.
ii. DRIVE CURRENT : It indicates the driving current.
iii. DRIVE TEMPERATURE : It indicates the driving temperature.
iv. SPEED SENSOR : - (Reserved)
v. DRIVE ACCEL VOLTS : It indicates the voltage of driving
acceleration.
vi. DRIVE ACCEL PERCENT : It indicates the driving acceleration as
percentages.
vii. BDI CHATGE REMAINING : It indicates the remaining level of
voltage on battery
viii. EXIT (ENTER) : It moves to the higher mode.
3. HYD SENSOR INPUTS: It shows the input values of hydraulic ADC. (It
contains lower modes)
i. HYD VOLTAGE : It shows the hydraulic voltage.
ii. HYD CURRENT : It shows the hydraulic current.
iii. HYD TEMPERATURE : It shows the hydraulic temperature.
iv. HYD ACCEL VOLTS : It indicates the voltage of hydraulic
acceleration
v. HYD ACCEL PERCENTAGES : It indicates the hydraulic acceleration
as percentages.
vi. EXIT (ENTER) : It moves to the higher mode.
4. EXIT (ENTER) : It moves to the higher mode.