EasyManuals Logo

CODEL Tunnel Tech 700 Series User Manual

Default Icon
81 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #17 background imageLoading...
Page #17 background image
Technical Manual CODEL
7
3.
Specifications
3.1.
General
Construction
- corrosion resistant epoxy coated aluminium housings sealed to IP66 (AQM & PSU)
- optional 316 stainless steel and 316 stainless steel TI for heads and brackets
Electro-magnetic immunity
- shielded to comply with 73/23/EEC - low voltage and 89/336/EEC-EMC
Ambient temperature
- -20
o
C to +50
o
C
3.2.
Power Supply Unit (PSU) (Optional)
Outputs
- 24V DC fused
- maximum current output must not exceed 5A (60W)
Power
- 90 to 264V AC, 47/63Hz, 100VA max.
Dimensions
- 230mm x 200mm x 110mm
3.3.
Air Quality Monitor
Monitoring channels
- up to 4 channels for CO, NO, NO², and visibility
Measurement path
- 3m (6m folded beam)
Measuring range (standard)
- Visibility: 0-0.015 m
-1
- CO: 0 - 300ppm
- NO: 0 - 30ppm
- NO²: 0 5/10ppm
- Other ranges selectable on setup
Averaging time
- 1 to 12 minutes