EasyManua.ls Logo

CODEL Tunnel Tech 700 Series - RS485 Interface

Default Icon
81 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Manual CODEL
8
Accuracy
- Visibility - ±0.002 m
-1
- CO - ±2ppm or 2% span
- NO - ±2ppm or 2% span
- NO² - ±100ppb
Power
- 24V DC, 24VA (obtained from PSU)
Communications
Serial RS485 interface via plug and socket for diagnostics, RS485 Modbus, or Codel
Protocol
Outputs
(Optional)
- analogue - 2 x 4-20mA, 200V Common
- max. load 500
- logic - 2 x volt-free contacts SPCO, 0.5A @ 125V AC,2A @ 30V DC, 0.5A @ 100V
DC (Per card, up to two cards per unit or system)
- Optional Modbus protocol serial communications (must be specified at the time of
order).
Dimensions
- Ø150mm x 260mm
3.4.
RS485 Interface (Optional)
Power
- 5V, 30mA obtained from AQM
PC Communications
- RS485 via 9-way ‘D’ connector
AQM Communication
- TTL levels
- connection via 4-way plug and socket
- isolated
Note: The AQM PCBs are equipped with built-in RS485 communications facilities for use during
commissioning. This facility may further be used after commissioning for communication to
integrate the AQM using MODBUS protocol fuller details are contained in Appendix A.