Error #7 No LSC-adjust
Cause:
Adjustment of label scanner not possible. The scanner is defective or it is scanned on label instead
of gap, or the backing paper is not transparent enough.
Solution:
Shift gap under label scanner and adjust it again. Possibly exchange defective scanner.
Error #8 Nonstopmode
Cause:
One of the labellers has an error. The nonstop mode does not function correctly. The error can be
triggered by all error messages.
Solution:
Eliminate the error on the labeller. Nonstop reset at both monitors.
Error #9 Label too long
Cause:
A leading label edge could not be scanned within the entered label length. The cause of this error
can be as follows:
Missing labels on the paper web
Slippage of the traction unit or loss of steps of the stepper motor due to hits on the paper web or
too high frictional force
Value of label length is entered too short
Predispensing greater than label length
Value of label length shorter than suppression of label scanning
Error of label scanning
Solution:
The following items may be helpful:
Enter in general double or three times the value of the label length
Correct predispensing
Adjust suppression of label scanning
Check label scanner and possibly clean it
Use unwinder with double dancer roller
Reduce friction force of entire paper web
Error #10 LSC Counter
Cause:
When braking the label, a gap was detected during predispensing. This happens in the case of
transparent or very reflective labels.
Solution:
Adjustment of suppression of label scanner
Optimizing the positioning of label scanner
Optimizing the label scanner sensitivity