Combilift Ltd C2500-C3000CB O&S Manual
4-11
C2500CB-OM-EN-11
The suction filter, located on the back of the tank, must be replaced initially
after 100 hours and then at intervals of every 500 hours (or 8 months
depending on which occurs first)
4.8: To replace the Suction Filter: (Service interval = 500Hours)
1. Loosen and remove the old filter cartridge.
2. Fill the new filter cartridge with hydraulic oil of the same grade as that
already in the tank.
3. Smear some of the oil on the O-ring seal on the top of the filter cartridge
4. Install the new filter cartridge onto the filter housing. Hand tighten the
cartridge into position.
5. Only use a genuine Combilift component.
Return Filter: (service Interval = 500 Hours)
The return filter, located on the top of the tank, must be replaced at intervals of
every 500 hours (or 8months depending on which occurs first).
To replace the Return Filter:
1. Remove the four bolts from the lid of the filter housing in order to gain
access to the filter element.
2. Remove the retaining spring from the top of the filter element
3. Remove the old filter element and replace with the new filter element.
Only use a genuine Combilift component.
4. Fit the retaining spring into the top of the filter element and refit the
housing lid.
In-Tank Strainer Filter: (Service Interval = 2000 Hours)
The In-Tank Strainer Filter, located in the bottom left hand corner of the tank,
must be replaced at intervals of every 2000 hours (or 24 months depending on
which occurs first). The strainer filter can only be accessed when the hydraulic
tank has been drained.
To replace the In-Tank Strainer Filter:
1. Drain the hydraulic oil tank through the drain plug in the bottom of the
tank
2. Remove the access panel on the side of the tank
3. Insert your hand into the tank and remove the filter by rotating it anti-
clockwise.
4. Fit the new strainer filter. Only use a genuine Combilift component.
5. Replace the access panel in the side of the tank, remembering to
correctly fit the access panel O-ring seal.
Change Hydraulic Oil (service interval = 2000Hours)
Drain Hydraulic system including tank. Once completed fill
system to the appropriate level with Hydraulic oil of the same
grade as that, which was already in the tank.
Capacity of Hydraulic oil in the Hydraulic system = 52 litres
approx