Compact Scaler Switcher
Comm-Tec S.r.l. 31 www.comm-tec.it
Command Example and
Feedback
Set whether to automatically send CEC
commands after signal detection.
[Param] = EN, Dis
EN - Enable (Default)
Dis - Disable
Get whether to automatically send CEC
commands after signal detection.
Set whether to automatically send RS232
commands after signal detection.
[Param] = EN, Dis
EN - Enable (Default)
Dis - Disable
Get whether to automatically send RS232
commands after signal detection.
Enable/disable auto standby after no signal
detection. [Param] = EN, Dis
EN - Enable
Dis - Disable (Default)
Get auto standby setting status.
Enable/Disable auto power off function of
relay. [Param] = EN, Dis
EN - Enable
Dis - Disable (Default)
Get auto power off setting status of relay.
Set the delay time to send CEC, RS232 and
standby commands after removing input
signal removed.
[Param] = 0~1800 (s) (Default: 600s)
Get the delay time to send CEC, RS232 and
standby commands after removing input
signal removed.
>SetOffMsgLoopCnt
[Param]
Set the number of times of sending Display
Off command. [Param] = 1 ~ 2 (Default: 1)
Get the number of times of sending Display
Off command.
>SetOffMsgLoopDelayT
ime [Param]
Set the delay time of sending Display Off
command.
[Param] = 5 ~ 100 (1=100ms) (Default: 10)
>SetOffMsgLoopDelayTime
5
Get the delay time of sending Display Off
command.