151
Down|Both]
switch(config-if)#event smtp both
show event
P
Show event selection
switch#show event
no event device-cold-
start
G
Disable cold start
event type
switch(config)#no event device-
cold-start
no event authentication-
failure
G
Disable Authentication
failure event typ
switch(config)#no event
authentication-failure
no event ring-topology-
change
G
Disable X-ring
topology changed
event type
switch(config)#no event ring-
topology-change
no event systemlog
I
Disable port event for
system log
switch(config)#interface
fastethernet 3
switch(config-if)#no event
systemlog
no event smpt
I
Disable port event for
SMTP
switch(config)#interface
fastethernet 3
switch(config-if)#no event smtp
show systemlog
P
Show system log
client & server
information
switch#show systemlog
Fault Relay Alarm Commands Set
Netstar Commands
Level
Description
Example
faultrelay power
G
Configure Relay Alarm
for Power Failure
switch(config)#faultrelay power 1
faultrelay
[enable|disable]
I
Configure Relay Alarm
for Port Link
Down/Broken
switch(config)#interface
fastethernet 3
switch(config-if)#faultrelay enable
no faultrelay
G
Disable Fault Relay
Alarm Function
switch(config)#no faultrelay

Table of Contents