Carousel Plus W Series Dryer
Options
• Volatile trap (only in conjunction with aftercooler) - The volatile trap is
recommended if drying materials that produce volatile that condense into a
waxy or oily residue and/or if the material contains excessive fines.
• Precooler - The precooler reduces the temperature of air flow after the desic-
cant wheel and before the process heater, enables the dryer to control tempera-
tures at low setpoints, (100º - 150ºF {38º - 66ºC})
• Dewpoint monitor/dewpoint control - The dewpoint monitor/dewpoint con-
trol allows the operator to monitor and control the performance of the dryer’s
dewpoint level, making energy savings possible by reducing the regeneration
temperature.
• Temperature setback - The temperature setback automatically reduces the
drying temperature to a lower standby mode when the machine throughput is
reduced or stopped, helping to minimize over drying material
• Audible/Visual alarms - The audible and visual alarms are a combination of a
blinking red alarm light and a horn that alerts the operator to a shutdown alarm.
• Filter check - The filter check sensor will activate a passive P10 alarm or a
shutdown A29 alarm when the process filter is clogged or needs to be replaced.
Description l 2-7
2
Description