This
manual
provides
the
set
up,
operating
instructions
and
servicing
information
for
the
Excalibur
Plus
PC™.
Electrosurgery
can
be
dan-
gerous
to
patients,
staff,
and
other
equipment
if
misused,
therefore,
please
understand
and
follow
the
warnings
and
cautions
that
are
included
in
this
manual.
Technical
specifications,
various
characteristic
performance
curves,
and
user
main-
tenance
instructions
are
also
included.
The
Excalibur
Plus
PC!"
provides
a
broad
range
of
capabilities
in
a
single
general
purpose
electro-
surgical
generator.
This
rugged
unit
fulfills
the
operational
and
safety
needs
of
the
modern
oper-
ating
room
by
providing:
*
Four
monopolar
cutting
modes.
*
Two
monopolar
coagulation
modes.
*
Two
bipolar
modes.
*
RF
isolated
and
independent
outputs.
*
The
proven
A.R.M.™
contact
quality
monitor-
ing
system.
*
Continuous
microprocessor
monitoring
to
pro-
vide
the
safety
required
by
the
conscientious
user.
Convenience
features
include:
+
Remote
Physician
Control
of
power
settings
using
standard
hand
switched
pencils
(PC
mode).
*
Independent
power
setting
for
each
mode.
*
Automatic
programming
restores
unit
to
the
last
settings used.
+
Easy
programmability
to
speed
set
up
of
the
unit.
General
Information
Section
1.0
*
Controlled
output
voltage
provides
superior
cut
independent
of
tissue
impedance.
*
Dual
activation
in
non-contact
coagulation
modes.
*
Ability
to
change
power
settings
from
the
con-
trol
panel while
the
unit
is
activated.
1.1
CAUTIONS
This
equipment,
in
conjunction
with
connect-
ed
accessories,
is
intended
to
produce
high-
frequency
electrical
energy
for
the
controlled
destruction
of
tissue.
Safe
and
effective
electrosurgery
is
dependent
not
only
on
equipment
design,
but
also
on
fac-
tors
under
the
control
of
the
operator.
It
is
important
that
the
instructions
supplied
with
this
equipment
be
read,
understood,
and
fol-
lowed
in
order
to
ensure
safety
and
effective
use
of
the
equipment.
1.1.1
CAUTIONS
For
Equipment
Preparation
+
Use
only
accessories
that
meet
the
require-
ments
of
Section
1.2
and
Figure
2.3.
*
Reusable
accessory
cables
should
be
periodi-
cally
function
and
safety
tested
in
accordance
with
the
original
manufacturer's
instructions.
*
Visually
inspect
all
accessories
before
each
use
to
verify
the
integrity
of
insulation
and
the
absence
of
obvious
defects.
In
particular,
elec-
trode
cables
and
endoscopic
accessories
should
be
checked
for
damage
to
the
insulation.
*
The
Excalibur
Plus
PC™
is
equipped
to
con-
nect
three
monopolar
accessories
at
one
time
for
the
convenience
of
the
surgical
staff.
Unused
accessories
should
be
stowed
in
a
safe,
electrically
insulated
place
such
as
a
noncon-
ductive
holster,
isolated
from
the
patient.
We
recommend
that
accessories
not
be
connected
unless
it is
known
that
they
will
be
needed.