EasyManua.ls Logo

Consilium SRT - Gate Array Output Signal; Gate Array Pulse Length Generator

Consilium SRT
120 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SRT X-BAND RADAR SYSTEMS
FUNCTIONAL DESCRIPTION
304202P003 3.9 Rev. C
3.2.1.6.6 Gate Array Output Signal
PCB
DATA BUS Bit DB0-DB7 of the Data Bus.
NMI Power supply line absence.
IRQ Video data Reception/Transmission Interrupt.
CK10 10 MHz clock
CS0-CS7 Digital potentiometer chip select.
U/D, INC Digital potentiometer control signals.
SWFIL1-2-3 Magnetron filament voltage control signals.
ANTS Antenna switch on signal.
SPA, MPA, LPA HVPS circuit control signals.
HVON HVPS circuit switch on signals.
SWB1-SWB2 Signals for the control of the NIFB bands.
TRPS Trigger PUSH for the transmission pulse generation.
TRPL Trigger PULL for the transmission pulse generation.
/TR Out Trigger for the display
/GSTC Gate for the STC signal generation.
TXCOMB Serial transmission of the combined video.
DIS TX Disabling for the combined transmission on the video.
TUNEN and /TUNEN Tuning detectors at transmission frequency
PM Out
SCK, SO Serial Gate Array management signals
3.2.1.6.7 Gate Array Pulse Length Generator
The Pulse Length Generator Function (Chapter 9, Figure 9.1.21) provides the
length of the generated pulse in accordance with the previous selections.
This function is performed by the Gate Array, which generates the signals
TRPS and TRPL when:
the signal TR is active
the signal HVOK is low
the 50 MHz clock is present
the signal RESET is high
the signal LINE is true
the signal SLK is high
the signal ANTBLK is high
Main Line 40VDC