SRT X-BAND RADAR SYSTEMS
CORRECTIVE MAINTENANCE
304202P003 6.1 Rev. C
CHAPTER 6
CORRECTIVE MAINTENANCE
6.1 General
6.1.1 Introduction
This chapter provides the procedure, which must be followed in order to replace
a faulty component of the SRT X-BAND transceiver according to the
troubleshooting procedures of Chapter 5.
6.1.2 Safety Precautions
If not otherwise specified in the procedures, during the corrective maintenance
operations, the following safety rules must be followed:
− each maintenance operation must be carried out only after the equipment
switching off
− before removing any component, be sure the spare part is available
− verify the integrity of the spare part and, if possible, perform a functional
test
WARNING
SET TO OFF THE MAIN BREAKER OF THE EQUIPMENT
AND HANG TO IT A PLACARD READING
<<WORK IN PROGRESS DO NOT SWITCH ON>>
6.1.3 Personnel
The replacement operations must be carried out exclusively by skilled personnel
with a good knowledge of the equipment.
6.1.4 Required Tools and Instruments
To carry out the replacement operations described in this chapter, only normal
workshop tools (as screwdrivers, wrenches etc.) are required.
The tools required to perform the troubleshooting operations are:
− set of screwdrivers;
− set of open wrenches;