Commander SE User Guide
Issue Number 5 43
Parameter 5 Set to PAd
Keypad control
Figure 6.7 Keypad connections
Used to start the Drive.
UsedtostoptheDrive. AlsousedtoresettheDriveafteratrip.
After a reset command, the Drive will need a start command to run.
Used to reverse the direction of rotation of the motor
(when parameter 26 = On).
Enter the motor current rating (taken from the motor name plate).
The Drive rated current value is the 100% RMS output current value of the Drive. This
value can set to a lower value but not a higher value.
Enter the rated full load speed of the motor (taken from the motor name plate).
Theratedspeedisusedtocalculatethecorrectslipforthemotor.
The rated speed is the synchronous speed - the 100% full load slip of the motor.
Example: For a 4 pole motor with a synchronous speed of 1500rpm and a slip speed
of 70rpm, enter 1430rpm in parameter 07.
A value of zero entered into parameter 07 means slip compensation is
disabled.
If the full load speed of the motor is above 9999rpm, enter a value of 0 in
parameter 07. This will disable slip compensation as values greater than9999
cannot be entered into this parameter.
Enter the motor rated voltage (taken from the motor name plate).
The motor power factor cos ϕ (taken from the motor name plate).
No. Function Type Limitations Range Units Defaults
06
Motor
rated
current
RW U 0 - Drive rated
current
A Drive rating EUR
Drive rating USA
No. Function Type Limitations Range Units Defaults
07
Motor
rated
speed
RW U 0 - 9999 rpm 1500 EUR
1800 USA
NOTE
NOTE
No. Function Type Limitations Range Units Defaults
08
Motor
rated
voltage
RW U 0 - 240
0 - 480
V 230/400 EUR
230/460 USA
No. Function Type Limitations Range Units Defaults
09
Motor power
factor
RW U 0 - 1.00 0.85 EUR
0.85 USA