EasyManua.ls Logo

Converteam MVS3007 - Page 111

Default Icon
114 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ALSPA PROFIBUS Field Bus Coupler Block Diagram
Page III
Profibus-DP Network
EXPANSION BUS DEVICE
SET UP & CONTROL
P74.00
FBC PROTOCOL
FBC NODE ADDRESS
CONFIGURE ON POWER UP
CONFIGURE
USE RECEIVED DATA
COMMUNICATIONS STATE
P74.01
P74.02
P74.03
P74.04
P74.05
P74.06
P74.09
FBC LOSS LOGIC & DIAGNOSTICS
TX ERROR WORD
TX ERROR COUNT
RX ERROR WORD
RX ERROR COUNT
P74.10
P74.11
P74.12
P74.13
FBC HEALTHY
97
P42.00 POINTER 1 SOURCE
POINTER 1 SCALE
X
POSSIBLE SOURCE FOR
SPEED REFERENCE P9.00
P42.01
P42.02
POINTER 2 SOURCE
POINTER 2 SCALE
X
POSSIBLE SOURCE FOR
SPEED REFERENCE P9.00
P42.03
P42.04
POINTER 3 SOURCE
POINTER 3 SCALE
X
POSSIBLE SOURCE FOR
REFERENCE SEQUENCER
P17.21
P42.05
P42.06
POINTER 4 SOURCE
POINTER 4 SCALE
X
POSSIBLE SOURCE FOR
PID SET POINT
P42.07
P42.08
POINTER 5 SOURCE
POINTER 5 SCALE
X
POSSIBLE SOURCE FOR
PID FEEDBACK
P42.09
P42.10
POINTER 6 SOURCE
POINTER 6 SCALE
X
POSSIBLE SOURCE FOR
TRIM REFERENCE
P42.11
P42.12
POINTER 7 SOURCE
POINTER 7 SCALE
X
POSSIBLE SOURCE FOR
SPEED TRIM REFERENCE
P42.13
P42.14
POINTER 8 SOURCE
POINTER 8 SCALE
X
POSSIBLE SOURCE FOR
TORQUE REFERENCE
P15.00
P42.15
P42.16
POINTER 9 SOURCE
POINTER 9 SCALE
X
POSSIBLE SOURCE FOR
TORQUE LIMITS
P42.17
P42.18
POINTER 10 SOURCE
POINTER 10 SCALE
X
POSSIBLE SOURCE FOR
TORQUE LIMITS
P42.19
P42.20
POINTER 11 SOURCE
POINTER 11 SCALE
X
POSSIBLE SOURCE FOR
TEMPERATURE
COMPENSATION SCALE
P42.21
P42.22
POINTER 12 SOURCE
POINTER 12 SCALE
X
POSSIBLE SOURCE FOR
FLUX LIMIT
P42.23
P42.24
POINTER 13 SOURCE
POINTER 13 SCALE
X
POSSIBLE SOURCE FOR
CURRENT LIMIT
P42.25
P42.26
POINTER 14 SOURCE
POINTER 14 SCALE
X
POSSIBLE SOURCE FOR
TORQUE/MAGNET.
CURRENT
P42.27
P42.28
POINTER 15 SOURCE
POINTER 15 SCALE
X
POSSIBLE SOURCE FOR
TORQUE/MAGENT.
CURRENT
P42.29
P42.30
POINTER 16 SOURCE
POINTER 16 SCALE
X
POSSIBLE SOURCE FOR
POSITION REFERENCE
P42.31
P42.32
POINTER 17 SOURCE
POINTER 17 SCALE
X
POSSIBLE SOURCE FOR
POSITION REFERENCE
P42.33
P42.34
POINTER 18 SOURCE
POINTER 18 SCALE
X
POSSIBLE SOURCE FOR
TACHO FEEDBACK
P42.35
REFERENCE POINTERS
ALSPA MV3000 Profibus Fieldbus Facility PPO Block Diagram
FBC 1 Issue 03/03
TO ANY DIRECTLY WRITABLE PARAMETER
FROM ANY PARAMETER
KEY
STATUS
FLAG
XXX
MONITOR
POINT
MULTIPLY
X
÷
+
+
DIVIDE
SUMMING
JUNCTION
DIGITAL
I/O SOURCE
TRIP 204 FBC LOSS
WARNING 106 FBC LOSS
P74.22 FBC REFERENCE 2
FBC FALLBACK 2P74.23
P74.20 FBC REFERENCE 1
FBC FALLBACK 1P74.21
P74.24 FBC REFERENCE 3
FBC FALLBACK 3P74.25
P74.26 FBC REFERENCE 4
FBC FALLBACK 4P74.27
P74.28 FBC REFERENCE 5
FBC FALLBACK 5P74.29
P74.30 FBC REFERENCE 6
FBC FALLBACK 6P74.31
P74.32 FBC REFERENCE 7
FBC FALLBACK 7P74.33
P74.34 FBC REFERENCE 8
FBC FALLBACK 8P74.35
REFERENCES
P74.40 CONTROL WORD 1
CONTROL FALLBACK 1P74.41
P74.42 CONTROL WORD 2
CONTROL FALLBACK 2P74.43
CONTROL WORDS
&
FREEZE/FALLBACK
FBC LOSS
P74.08
POSSIBLE SOURCES FOR ANY
OF THE DRIVE CONTROL FLAGS
OR DIGITAL OUTPUT BITS
TRANSMIT PPO
RECEIVE PPO
WORD 6
WORD 7
WORD 8
PPO WORD 5 POINTER
PPO WORD 5 SCALER
PPO WORD 6 SCALER
PPO WORD 6 POINTER
PPO WORD 7 POINTER
PPO WORD 7 SCALER
PPO WORD 8 POINTER
PPO WORD 8 SCALER
X
X
X
X
SCALING
P74.58
P74.59
P74.60
P74.61
P74.62
P74.63
P74.64
P74.65
Profibus-DP Interface
WORD 5
P74.36 FBC REFERENCE 9
FBC FALLBACK 9P74.37
P74.38 FBC REFERENCE 10
FBC FALLBACK 10P74.39
FBC PPO TYPE
WORD 2
WORD 3
WORD 4
PPO WORD 1 POINTER
PPO WORD 1 SCALER
PPO WORD 2 SCALER
PPO WORD 2 POINTER
PPO WORD 3 POINTER
PPO WORD 3 SCALER
PPO WORD 4 POINTER
X
X
X
X
P74.50
P74.51
P74.52
P74.53
P74.54
P74.55
P74.56
WORD 1
PPO WORD 4 SCALER P74.57
WORD 9
WORD 10
PPO WORD 9 POINTER
PPO WORD 9 SCALER
PPO WORD 10 POINTER
PPO WORD 10 SCALER
X
X
P74.66
P74.67
P74.68
P74.69
WORD 6
WORD 7
WORD 8
WORD 5
WORD 2
WORD 3
WORD 4
WORD 1
WORD 9
WORD 10
PPO WORD 5 POINTER
PPO WORD 5 SCALER
PPO WORD 6 SCALER
PPO WORD 6 POINTER
PPO WORD 7 POINTER
PPO WORD 7 SCALER
PPO WORD 8 POINTER
PPO WORD 8 SCALER
X
X
X
X
P74.78
P74.79
P74.80
P74.81
P74.82
P74.83
P74.84
P74.85
PPO WORD 1 POINTER
PPO WORD 1 SCALER
PPO WORD 2 SCALER
PPO WORD 2 POINTER
PPO WORD 3 POINTER
PPO WORD 3 SCALER
PPO WORD 4 POINTER
X
X
X
X
P74.70
P74.71
P74.72
P74.73
P74.74
P74.75
P74.76
PPO WORD 4 SCALER P74.77
PPO WORD 9 POINTER
PPO WORD 9 SCALER
PPO WORD 10 POINTER
PPO WORD 10 SCALER
X
X
P74.86
P74.87
P74.88
P74.89
FBC LOSS ACTION
P74.07
WORDS 1 TO 6 ACTIVE FOR
PPO TYPES 2, 4 AND 5.
WORDS 7 TO 10 ACTIVE
FOR PPO TYPE 5 ONLY

Table of Contents