ELECTRICAL AND PNEUMATIC HOOK-UPS
WARNING
All operations required for the electrical hook-up of the machine must be carried
out exclusively by a qualified electrician.
- The electrical supply must be suitably sized in relation to:
• absorbed power specifications indicated on the machine dataplate.
• the distance between the machine and the power supply hook-up point, so that
voltage drops under full load do not exceed 4% (10% in the case of start-up) below
the rated voltage specified on the dataplate.
- The user must equip the machine with the following:
• a dedicated power plug in compliance with the relevant electrical safety standards.
• a suitable circuit-breaker (residual current set to 30 mA) on the mains connection
• power line fuses in accordance with specifications in the main wiring diagram of this
manual.
• a suitable earthing system installed on the workshop mains line
- To prevent unauthorised use of the machine, always disconnect the mains plug when
the machine is not used (switched off) for extended periods of time.
- If the machine is connected directly to the power supply by means of the main elec-
trical panel and without the use of a plug, install a key-operated switch or suitable
lock-out device to restrict machine use exclusively to qualified personnel.
WARNING
For correct and safe operation, the machine must be suitably earthed.
NEVER connect the earth to a gas pipe, water pipe, telephone line or other make-
shift system. (identico**)
- To ensure correct operation, the pneumatic circuit must remain between minimum 8
bar and maximum 16 bar.
NOTE
The machine is equipped with a pressure regulator set at 10 bar (standard machine
operation). If you are working with easily deformable rims (motor cycle wheels for
example) we recommend lowering the pressure temporarily to 7 or 8 bar.