40 JOLLY Operator’s manual
Vertical clamping inoperative
Clamping plate not adjusted
➥ Adjust clamping plate
Clamping plate faulty
➥ Renew clamping plate
Tyre pressure gauge needle fails to return to 0.
Pressure gauge faulty or damaged
➥ Renew pressure gauge
WARNING
The “Spare parts” handbook does not authorise the user to carry out work on the
machine with the exception of those operations explicitly described in the user’s
manual, but enables the user to provide the technical assistance service with preci-
se information, in order to reduce delay.
MAINTENANCE
WARNING
Corghi declines all liability for claims deriving from the use of non-original spares or
accessories.
WARNING
It is expressly forbidden to attempt to alter operating pressure of the relief valves
or the pressure regulator.
The manufacturer declines all liability for damage resulting from tampering with
these components.
WARNING
Before making any adjustments or carrying out maintenance, disconnect the electri-
cal supply from the machine and make sure that all moving parts are suitable immo-
bilised.
WARNING
Do not remove or modify any parts of this machine except in the case of service
interventions.
DANGER
When the machine is disconnected from the air system, the devices bearing the abo-
ve plate may remain pressurized.
The FRL unit (filter, regulator and lubricator) is installed to filter the air, regulate its
pressure and lubricate it.