38 JOLLY Operator’s manual
- Press the inflation pedal fully down for a short period to the bead seating position
(fig. 30a). The tyre will expand and the beads will seat.
- Continue to press the pedal in the inflation position (fig. 30b) until the beads are
completely sealed.
Note: to improve the operation of the tubeless tyre inflation system the compressed
air line pressure must be between 8/10 bar.
TROUBLE SHOOTING
When you press the table top rotation pedal the table top will not rotate.
Power cord conductor shorting to ground
➥ Check the wiring
Motor shorted
➥ Renew the motor
Inverter short-circuit
➥ Renew inverter
Fuses blow
➥ Check and renew fuses
Rotation control pedal fails to return to the central position
Control spring broken
➥ Renew the spring
Bead breaker pedal and table top pedal do not return to home position.
Control spring broken
➥ Renew the spring
No oil in lubricator
➥ Top up lubricator with SAE20 non-detergent oil.
Internal air leak (Take off the left cover and locate the leak)
Air leak from bead breaker cock
➥ Renew the cock
➥ Renew bead breaker cylinder
Air leak from the table top cock
➥ Renew table top cylinder
➥ Renew swivel connector
Bead breaker cylinder lacks force, fails to break beads and leaks air
Silencer plugged
➥ Renew silencer
Cylinder seals worn
➥ Renew seals