38 JOLLY Operator’s manual
- Press the inflation pedal fully down for a short period to the bead seating position
(fig. 30a). The tyre will expand and the beads will seat.
- Continue to press the pedal in the inflation position (fig. 30b) until the beads are
completely sealed.
Note: to improve the operation of the tubeless tyre inflation system the compressed
air line pressure must be between 8/10 bar.
TROUBLE SHOOTING
When you press the table top rotation pedal the table top will not rotate.
Power cord conductor shorting to ground
Check the wiring
Motor shorted
Renew the motor
Inverter short-circuit
Renew inverter
Fuses blow
Check and renew fuses
Rotation control pedal fails to return to the central position
Control spring broken
Renew the spring
Bead breaker pedal and table top pedal do not return to home position.
Control spring broken
Renew the spring
No oil in lubricator
Top up lubricator with SAE20 non-detergent oil.
Internal air leak (Take off the left cover and locate the leak)
Air leak from bead breaker cock
Renew the cock
Renew bead breaker cylinder
Air leak from the table top cock
Renew table top cylinder
Renew swivel connector
Bead breaker cylinder lacks force, fails to break beads and leaks air
Silencer plugged
Renew silencer
Cylinder seals worn
Renew seals