General Information
Page A14
The following remote ice makers incorporate the mixing valve in the condenser. This configuration allows
up to a 100 foot calculated remote line set run. Reference the diagram below to calculate the maximum 100
foot line set run.
Ice Machine Model Number Remote Condenser Model Number
CCM2148R*1 RC21002C
CCM1848R*1 RC21002C
CCM1448R*1 RC14002C
CCM1530R*1 RC14002C
CCM1030R RC08002
CCM0830R RC08002
CCM0630R RC06002
CCM0530R RC05001
Limitations for remote machines that have the mixing valve mounted in the condenser.
Maximum Rise is 35 feet.
Maximum Drop is 15 feet.
Maximum equivalent run is 100 feet.
Formula for figuring maximum equivalent run is as follows:
Rise x 1.7 + Drop x 6.6 + horizontal run = equivalent run.
Examples: 35 ft. rise x 1.7 + 40 ft. horizontal = 99.5 equivalent feet line run
35 ft. rise
40 ft. horizontal
10 ft. drop x 6.6 + 34 ft horizontal = 100
equivalent feet line run
10 ft. dro
p
34 ft. horizontal

Table of Contents