24
ENGLISH
Snooze
• When thealarm sounds, press [ SNOOZE/LIGHT ] to temporarily silence thealarm
for 5 minutes. Thealarm symbol will continue to flash.
• To permanently silence thealarm, press one of theother buttons: [ CHANNEL/+ ],
[ MODE/SET ], [ MAX/MIN/ALARM ] or [ HISTORY/− ].
Calibration
• If theconnected sensors display inaccurate values, they can be recalibrated.
To calibrate thesensors properly, you must have reference values from meters/
sensors that you know give accurate readings.
• Thecalibrated value can only be displayed on theindoor unit. Theexternal
thermometers/hygrometers always show theuncalibrated value.
• Therange for relative humidity is always between 10 and 99%. It is not possible to
adjust thevalue beyond this range.
• Press [ CHANNEL/+ ] or [ HISTORY/− ] to increase or decrease theselected value.
To change thevalue more quickly, press and hold thebutton for 3 seconds.
• Press [ MAX/MIN/ALARM ] to reset theadjusted value.
• To complete thecalibration and return to thenormal display mode, press
[ SNOOZE/LIGHT ] or wait for 30 seconds.
Temperature
1. In normal mode, press and hold [ MODE/SET ] and [ CHANNEL/+ ] simultaneously
for approx. 5 seconds to enter calibration mode. Thevalue for theindoor unit’s
temperature will begin to flash.
2. Adjust thevalue to correspond with your reference value. Thevalue can be
changed in steps of 0.1 °C.
3. Press [ MODE/SET ] to calibrate theexternal sensor’s value.
4. If you have several external sensors connected, press [ MODE/SET ]
repeatedly to scroll through thechannels (1–8) and adjust in thesame way as in
point 2.
Relative humidity
1. In normal mode, press and hold [ MODE/SET ] and [ HISTORY/− ] simultaneously
for approx. 5 seconds to enter calibration mode. Thevalue for theindoor unit’s
humidity will begin to flash.
2. Adjust thevalue to correspond with your reference value. Thevalue can be
changed in steps of 1 %.
3. Press [ MODE/SET ] to calibrate theexternal sensor’s value.
4. If you have several external sensors connected, press [ MODE/SET ] repeatedly to
scroll through thechannels (1–8) and adjust these in thesame way as in point 2.