EasyManua.ls Logo

COX CXO300 - Bringing out of Storage

COX CXO300
92 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7.0 STORAGE 81
CXO300 OWNER’S MANUAL
7.2 BRINGING OUT OF STORAGE
When intending to bring your outboard(s) out of storage after a period of one month or longer, the
following precautions will return it to operating condition.
1 Inspect the exterior of your outboard(s) for any obvious damage or degradation, including
corrosion. Contact an authorized Cox Powertrain dealer if any areas of concern are identified.
2 Inspect the fuel system lines and correct any issues prior to attempting to operate your outboard(s).
Confirm that the water separator drains are closed and tight.
3 Lubricate all lubrication points with marine grease.
4 Check the levels of powerhead and transmission oils and top-up as necessary. Visually inspect the
powerhead while the top cowling is removed.
5 Note the age of any diesel fuel stored in your vessel. Diesel fuel has a typical storage life of 6-12
months, which includes any time prior to storage of your outboard(s), and it may be necessary to drain
and fill with fresh diesel following a long period of storage.
6 Check the state of charge on your battery, then if acceptable, connect the positive terminal first, then
the negative terminal.
7 If using a tilt support bracket, remove it and bring your outboard(s) to the vertical position.
8 Apply marine grease to the propeller shaft splines, then reinstall the propeller.
9 Identify and follow any instructions for other components in your installation such as your steering and
controls gear, other electronic components, any bilge pumps etc.