BevMax_Media_Programming_10_6_10 Page 19 of 106 08/15/2013
Condenser High Side Temperatures at or nearing 150 degrees are being Clean screens and condenser.
Warning. Reported. Check to see that the machine has six inches off
clearance from the wall.
Replace the sensor.
Condenser High Side Error. Temperatures of an unlikely nature are being Check the temperature sensor and connections.
Reported (such as 999 degrees). Cooling functions Replace the temperature sensor.
are stopped.
Evaporator Coil Low Side The control board has recorded sensor readings that Check for evaporator fan function.
Warning. are nearing or outside of allowed parameters. Check for ice buildup on evaporator.
Check for excessive moisture.
Evaporator Coil Low Side The control board has recorded sensor readings that Check for evaporator fan function.
Error. are outside of allowed parameters. Cooling functions Check for ice buildup on evaporator.
are stopped. Check for excessive moisture.
Replace the temperature sensor.
IO Even Input Short. The I/O board is reporting that an even input switch Check for motor errors (out of home position)
has shorted out. replace the I/O board.
IO Odd Input Short. The I/O board is reporting that an odd input switch Check for motor errors (out of home position)
has shorted out. replace the I/O board.
Sold Out Machine. The control board has determined that all selections Check SureVend settings and function.
in the machine are sold out. Check for vend motor function.
Check harnessing connections.
Check for board function (selection configuration).
Recycler Motor Problem. A problem has been detected with a motor inside Check for an obstruction or blockage within the
the bill validator. recycler which is stopping the motor from completing
its cycle.
Replace the bill validator.
Recycler Sensor Problem. A problem has been detected in a sensor within Replace the recycler cassette.
the recycler. Replace the bill validator.