BevMax_Media_Programming_10_6_10 Page 20 of 106 08/15/2013
Recycler Jam. The recycler is unable to function. Check for an obstruction or blockage which is
preventing the recycler from completing its cycle.
Replace the recycler cassette.
Replace the bill validator.
Recycler Checksum Error. A communications error has been reported Check the bill validator harnessing for damage.
between the recycler and the control board. Re-start the system to restore communication.
Replace the recycler.
Recycler Disabled. The recycler has been disabled by the control board. Check for proper function of the recycler unit (errors).
Check the recycler cassette for proper installation.
Replace the bill validator.
# XX Coin Mech Tube Empty. The coin mechanism is reporting that there is an Check for an empty tube and replenish.
empty payout tube. (# XX indicates which tube is Check for a bad sensor.
empty). Replace the coin cassette.
Replace the coin mechanism.
Bill Validator Stacker Motor An error has been reported concerning the stacker Check the bill path for a blockage preventing the
Error. Motor in the bill validator. proper operation of the bill stacker motor.
Replace the bill validator.
Bill Validator Recycler Gate An error has been detected in the recycler gate Check for an blockage in the bill path preventing the
Error. gate from functioning.
Replace the bill validator.
Bill Validator Recycler Tape An error has been reported in the operation of Check for a blockage in the bill path which prevents
Error. the recycler tape within the recycler cassette. the tape from moving backward and/or forward.
Replace the recycler cassette.
Replace the bill validator.
Optical Sensor Failure. The failure of an optical sensor within the Check the bill path for an obstruction or blockage
bill validator has been detected. which prevents the optical sensor from functioning.
Replace the bill validator.
Magnetic Sensor Failure. The failure of the magnetic sensor within the Check the bill path for an obstruction or blockage
bill validator has been detected. which prevents the magnetic sensor from functioning.
Replace the bill validator.