BevMax_Media_Programming_10_6_10 Page 21 of 106 08/15/2013
Recycler Cass Jammed. The recycler cassette is not able to move. Check for an obstruction or blockage which is
preventing the cassette from moving.
Replace the recycler cassette.
Replace the bill validator.
Bill Validator Path Jammed. A blockage of the bill path has been reported. Check for an obstruction or blockage which is
preventing the bills from moving thru the bill validator.
Replace the bill validator.
Bill Validator Cashbox The bill box has become jammed and is not Check for a full bill box
jammed. allowing the stacker motor to complete its cycle. Check for damaged bills blocking the operation of the
stacker plate.
Replace the bill box.
Replace the bill validator.
Stacker Out Of Position. The control board has detected that the stacker Check for a blockage or obstruction which is not
has stopped out of its home position. allowing the stacker motor to complete its cycle.
Check for proper installation of the bill box.
Replace the bill box.
Replace the bill validator.
Recycler Out Of Position. The recycler is not able to accept bills. Check for proper installation of the recycler cassette.
Check for an obstruction or blockage which is
preventing the cassette from locking into position.
Replace the recycler cassette.
Replace the bill validator.
Cold Drink X Motor Failure. The control board is reporting that the X motor is Check for proper connections to the motor.
not functioning. Check for damage to the harnessing.
Check for proper switch function.
Check for over tightening of the motor.
Replace the motor.
Cold Drink Y Motor Failure. The control board is reporting that the Y motor is Check for proper connections to the motor.
not functioning. Check for damage to the harnessing.
Check for proper switch function.
Check for over tightening of the motor.
Replace the motor.
ErrorDescription ProbableCausePossibleSolutions