BevMax_Media_Programming_10_6_10 Page 22 of 106 08/15/2013
Cold Drink Picker Motor The control board is reporting that the picker motor Use the position test functions to test the picker motor.
Failure. is not functioning. Replace the picker cup.
Cold Drink Port Motor The control board is reporting that the port motor Use the port test functions to test for function
Failure. is not functioning. Check wiring connections.
Check switch functions including the position cam.
Replace the motor.
Cold Drink Vend Timeout. The control board is reporting that a successful vend Check for a picker cup that did not return to the home
cycle has not been completed in the allowed amount position.
of time. Check for a port door that did not open/close."
Cold Drink Cabinet Failure. An error that has not yet been defined. Should not be seen in a machine.
Replace the control board.
Cold Drink Coin Return The control board is reporting that the coin return Check the wiring connections.
Motor Failure. Motor has failed. Check for proper mounting of the motor.
Check for proper mounting of the coin mechanism.
Replace the coin return motor.
Cold Drink Picker Home The control board has reported that the picker Use the position test functions to test or cycle the
Failure. has failed to return to its home position at the picker back to its home position.
end of a cycle. Replace the picker cup.
Cold Drink Temperature The control board is reporting that the Compare the reported temperature against a
Sensor Error. temperature sensor has failed. Thermometer.
Replace the temperature sensor.
Cold Drink Cooling System The control board is reporting that the refrigeration Check for a bad temperature sensor.
Not Cooling. system is not functioning. Check for other errors that would cause the
refrigeration system to have been shut down
by the board.
Cold Drink Cabinet Too Hot. The control board is reporting that the cabinet is Check for an accurate temperature reading.
operating at three degrees, or more, above the Check refrigeration system for proper function
allowed parameter. (clean screens, condenser also distance from rear wall).
Check for proper fan operation.