BevMax_Media_Programming_10_6_10 Page 23 of 106 08/15/2013
Cold Drink Cabinet Too Cold. The control board is reporting that the cabinet is Check for an accurate temperature reading.
operating at three degrees, or more, below the Check refrigeration system for proper function
allowed parameter. (clean screens, condenser also distance from rear wall).
Check for proper fan operation.
Card Reader Manuf Trans The card reader has reported an error in Check the card reader for proper function.
Error. transmitting data. Replace the card reader.
Card Reader Service Error. An internal error has occurred within the card Reset the card reader and retry.
reader. Replace the card reader.
Card Reader Manufact Error. An internal error has occurred within the card Reset the card reader and retry.
reader. Replace the card reader.
Card Reader Failed OOS Error. An internal error has occurred within the card Reset the card reader and retry.
reader. Replace the card reader.
Card Reader Comms OOS An internal error has occurred within the card Reset the card reader and retry.
Error. reader. Replace the card reader.
Card Reader Jam OOS Error. An internal error has occurred within the card Reset the card reader and retry.
reader. Replace the card reader.
Card Reader Manufact OOS An internal error has occurred within the card Reset the card reader and retry.
Error. reader. Replace the card reader.
Health Check Error. The control board is reporting that an error occurred Check temperature sensors for proper function.
in the process of conducting a health check. Check the refrigeration system for function.
Reset machine for another cool down period to check
for proper health control function.
Reset the control board to default settings and set up
for another test.
Replace the control board and re-test.
Heath Timer Error. The control board is reporting that an error has Reset machine for another cool down period to check.
occurred in the operation of the timer during a for proper health control function.
health check function. Reset the control board to default settings and set up
for another test
Replace the control board and re-test.
ErrorDescription ProbableCausePossibleSolutions