BevMax_Media_Programming_10_6_10 Page 24 of 106 08/15/2013
Health Recheck Error. The control board is reporting that an error Check temperature sensors for proper function.
occurred in the process of conducting a second Check the refrigeration system for function.
attempt at a health check. Reset machine for another cool down period to check
for proper health control function.
Reset the control board to default settings and set up
for another test.
Replace the control board and re-test.
Capacity Sensor Failure. An error has been reported with a sensor inside Re-start the bill validator and check function.
the bill validator. Replace the bill validator.
Not Calibrated Sensor Error. An error has been reported with a sensor inside the Re-start the bill validator and check function.
Bill validator. Replace the bill validator.