25
Fan Control
NOTE: Fan control is applicable to the DM-NVX-D30 and DM-NVX-D80-IOAV only.
Configure fan control or view fan status using the web interface or SIMPL Windows.
Using the Web Interface
Configure fan control on the Device page. In the Fan Control section, set Fan Mode to
one of the following:
• Auto: (Default setting) The fan automatically turns off when the following two
conditions exist:
1. No video stream is present.
2. The internal temperature of the device does not exceed the normal operating
range.
• Always On: The fan runs continuously regardless of video stream status and
internal temperature of the device.
Fan status is indicated as either of the following:
• Full On: The fan is running.
• Off: The fan is not running.
Device Page – Fan Control
Using SIMPL Windows
Using the top-level programming slot for the DM-NVX-D30, set the <FanControl>
analog input join to the desired setting. The <FanControl_F> analog output join reports
the fan mode of operation. The <FanStatus_F> analog output join reports the fan
status. For additional information, refer to the SIMPL Windows help file.