Minimum cross-section 0,25mm
2
Cross-section 0,25mm
2
(Shielded or twisted pair
recommended)
Drives controlling (STEP/DIR)
Cross-section 0,25mm
2
; shielded–twisted. You can possibly
use the FTP computer cable.
Please note that for signals
(STEP + / STEP-) (Dir+ / Dir-
) you should always use twisted
pair cables.
Ethernet Communication wire
Standard Ethernet cable, shielded - FTP, cat. 6. See 4.7
Min. Cross-section 0,5mm
2
If modules are mounted on the same DIN rail next to the
controller you can use DB9 plugs clenched on the 9-wire tape
(if further – use shielded twisted pair).
During mechanical and electrical mounting – particular caution is advised. Poorly tightened cable
may cause many trouble; it’s also very difficult to find such a defect while launching/using the
system.
CS- Lab s.c. – CNC CSMIO/IP- M controller
Page 16