LCD Contrast
The LCD Contrast (screen contrast) may be adjusted as desired. Contrast settings range from
01 to 15. Setting changes can be viewed on the screen during adjustment.
1. Press MODE/COIN to move the cursor to the bottom menu line.
2. Press CONT to select a setting between 01 and 15.
Auto Oiler (Optional)
JetSort has an optional auto oiler for high volume U.S. gold dollars or with non-U.S. coin sets.
If the machine is installed with an oiling kit, the Oil option should be On. This setting allows a
small drop of oil to be dispensed onto the sorting disk to lubricate coins.
The amount of oil dispensed onto the sorting disk is determined by the volume of coin
processed. The Coin setting may be set from 1 to 99. This numeric setting represents “coins in
oil per thousand.” A setting of 4 or 5 is recommended for standard use. For example, if 4 is
entered, a drop of oil will be dispensed every 4,000 coins. For additional information about
coin-volume settings, contact a Cummins Allison representative.
The Pulse determines the length of time the auto oiler motor will be on when it is activated to
dispense oil. In most circumstances, the factory setting of .10 (one-tenth of a second) is
recommended.
Press MODE/COIN to move the cursor to the bottom menu line.
1. Press CONT to select On or Off. If On is selected, proceed to steps 3 and 4. If Off is
selected, exit feature menu.
2. Press > to scroll forward to Coin. Enter numeric setting as recommended by a Cummins
Allison Service Representative. Press RCPTS/ENTER.
3. Press > to scroll forward to Pulse. Enter numeric setting as recommended by a
Cummins Allison Service Representative. Press RCPTS/ENTER.