Error recovery
If a jam occurs while sorting coin, or if there is a sensor malfunction, the JetSort immediately
stops, the red error light flashes and the display blinks one of two error messages:
• SENSOR ERROR – jam has occurred at the sensor
• TABLE ERROR –table has stopped rotating or slowed.
Using metallic tool could cause sensor damage.
Always use non-metallic tool.
SenSensor error recovery
1. Press CLEAR to determine location of the obstruction.
2. Remove the inspection tray and, using a non-metallic tool, clear the blocked sensor.
3. If the sensor has not been adequately cleared or another sensor is blocked, the blocked
sensor is indicated on the screen. Repeat step two.
If the sensor has been cleared, the VERIFY OR CONT screen appears.
4. To continue transaction, press CONT. If verification of processed coin is necessary,
follow the instructions under Reconcile Batch – after Table Error Recovery.