26
Curtis 1220 Manual, Rev. C
4 — MONITOR MENU: Controller
Monitor Menu: CONTROLLER Status
DISPLAY
VARIABLE RANGE DESCRIPTION
Interlock Off / On Flag indicating the interlock status.
Traction Controller Off / On Flag indicating the status of communcation
Connected
between the steer controller and the traction
controller.
Monitor Menu: CONTROLLER
DISPLAY
VARIABLE RANGE DESCRIPTION
Temperature -50°C 100°C Controller’s internal temperature.
Motor RPM -8000 8000 rpm Steer motor speed in revolutions per minute.
Motor Current -60 60 A Current of the steer motor.
Motor Temp Cutback 0 100 % Current cutback, as a percentage of max
current, during motor over-temperature.
100% = no cutback.
Traction Motor RPM
-8000 8000 rpm Traction motor speed in revolutions per minute.
Hour Meter 0 1000000.0 h Number of hours KSI has been active.

Related product manuals