Return to TOC Curtis 1239E-1269E Manual, os 37.0 RevA – May 2021
4 — PROGRAMMABLE PARAMETERS
pg. 33
Note: All bit variables have two VCL parameter names. e rst is the name of the bit, and the second
is the name of the byte containing the bit. e bit position within the byte is indicated in brackets
aer the byte name.
Examples:
BIT NAME: Metric_Units
BYTE NAME: OptionBits3 [Bit 5]
BIT NAME: Encoder_Fault_Detection_Enable
BYTE NAME: Encoder_Fault_Detection_Enable_Bit0 [Bit 0]
In the second example, “_Bit0” is part of the byte name, and does not indicate the bit position; this
byte, like all bytes, has 8 available bits.
Within the menu charts, each pair of bit variable names is shown as a grouped set, with the bit name
appearing rst and then the byte name:
Metric Units On/Off
|Metric_Units On/Off
|OptionBits3 [Bit 5]
SDO Write Message
To retain parameter values changed via CANopen SDO write messages following a key-cycle, write a
non-zero value to CAN_EE_Writes_Enabled (object index 0x332F, subindex 0x00) before changing
parameter values. is will cause changes to be written to non-volatile memory immediately. Aer
completing the changes, write the value zero to CAN_EE_Writes_Enabled.
Do not leave CAN_EE_Writes_Enabled at a non-zero value during normal operation, because
damage to the controller’s EEPROM may occur.
CAUTION
Individual parameters are presented as follows in the menu charts:
Motor Technology 0 – 1 Set this parameter to the type of motor in the vehicle:
0 = ACIM (induction motor)
1 = PMAC (permanent magnet synchronous motor)1
Note: A Parameter Mismatch Fault will result unless the
Feedback Type matches the Motor Technology setting:
If Motor Technology = 0 (ACIM), then the Feedback Type
must = 1 (quadrature encoder).
If Motor Technology = 1 (PMAC), then the Feedback Type
must = 2 (sin/cos device).
Motor_Technology 0 – 1
0x3814 0x00
[PCF]
Parameter name
as it appears in the
programmer display.
Parameter name
in VCL.
CAN object index
and subindex.
Allowable range in the
programmer’s units.
Allowable range
in VCL units.
Description of parameter’s function and,
where applicable, suggestions for setting it.

Table of Contents