8A — AUTOMATED ACIM MOTOR CHARACTERIZATION PROCEDURE
pg. 95
Turn o encoder fault detection (Motor » Encoder Fault Setup » Fault Detection Enable).
While applying and holding full throttle, adjust SlipGain until the peak torque is measured.
To have the encoder fault detection active (recommended), turn it back on (now).
14.2 Alternately, the vehicle can be used as the “draw bar test” by accelerating the motor to
a predetermined speed (rpm)— with the quickest time corresponding to the optimum
SlipGain. is method uses the controller’s time-to-speed function. e test-acceleration
will be at full controller current.
Begin by setting the corresponding Accel Rates to very fast values, based upon the applications
Control Mode.
Speed Mode Express: Accel Rate.
Speed Mode: Full Accel LS, Full Accel HS, Low Accel.
Torque Mode: Accel Rate. (this is the typical 1239E/1269E usage)
On the 1313 programmer, add these two items to the Favorites shortcut, to easily toggle between them:
Monitor » Vehicle » Time to Speed 1
Program » Motor Control Tuning » IM Motor Characterization Tests » SlipGain.
Next, set the Capture Speed 1 parameter to an rpm enveloping the motors desired maximum torque
range. e monitor item, Time to Speed 1, will record the time taken for the vehicle (motor) to go
from zero rpm to the programed Capture Speed 1 during its most recent acceleration.
To perform the test, from a stop, accelerate the vehicle through the predetermined speed. e
timer starts counting when full throttle is applied, and stops counting when the speed is reached.
A built-in trigger will allow the test to begin again once the vehicle comes to a stop and the
throttle is re-engaged, so be sure to note the value of the test rst before accelerating-away in
subsequent runs. Each time, adjust the SlipGain value until the Time to Speed 1 is minimized.
is test should be run repeatedly over the same stretch of at or uphill ground. Loading the vehicle
will improve results, the idea being to have the motor produce maximum torque as in the draw-
bar method. Work quickly, to avoid excessive motor heating, to obtain the most accurate results.
15. Run the FW Base Speed test.
Set the FW Base Speed to 6000 rpm. The test should be run with batteries that have a
reasonable charge.
Motor » Control Algorithms » 0-ACIM » Field Weakening Control » FW Base Speed
Set the Accel Rates to be very fast, so that the vehicle will be accelerating at full current during
the test. From a stop, quickly apply full throttle to accelerate to a high speed. Aer the motor
settles at a speed for a moment, release the throttle to stop the test run. Note the value of the
Base Speed Captured (Monitor » Controller » Motor Tuning » Base Speed Captured), and enter
this value for the FW Base Speed setting.
Note:
e base speed capture test restarts each time the vehicle comes to a stop and the throttle is
released, so be sure to note the value before driving (accelerating) away.
This FW Base Speed parameter not only needs to be set during initial setup, yet reset each
time the Motor Type or the low speed current limit is changed. For example, if the Drive_
Current_Limit or PL_Drive_Nominal parameters are lowered (changed), retest and reset
this parameter.
Quick Links:
SlipGain p.58
Fault Detection Enable p.67
Torque Mode p.43
Accel Rate
Capture Speed 1 p.72
Time to Speed 1 p.84
Quick Links:
Drive_Current_Limit p.46
PL_Drive_Nominal p.47
FW Base Speed p.59
Base Speed Captured p.83