User Manual – CybTouch series
CybTouch Series – User Manual
The pump motor needs to be on for the sequence to start.
The part-program memory is full, you cannot add another
sequence.
The level code to access the selected page is not correct. Try again
or ask for it if you do not have it.
The loaded part-program is incompatible with the NC. This part
should be deleted.
Machine parameter file
problem
This file is corrupt and cannot be saved. Try to restart the NC. If the
problem persists, format the memory.
Machine parameters not
compatible, please format data
This message appears when a software update has been made over
a much older version and the parameters are no longer compatible.
It can also appear if the uploaded parameters (with RFlink) are
much older or newer than the current software version and they are
not be compatible. A new start-up of the machine must be made.
Contact your dealer.
Lismisc File not compatible
Information message, which will disappear when restarting the NC.
This file is corrupt and cannot be saved. Try to restart the NC. If the
problem persists, format the memory.
A file is missing, and the code indicates which one. Call Cybelec with
this code to know which file is missing.
This file is corrupt and cannot be saved. Try to restart the NC. If the
problem persists, format the memory.
Operator entered a value under the limit, or a memorized value in
the program is under the limit. The wrong value flashes and must be
corrected.
Operator entered a value over the limit, or a memorized value in
the program is over the limit. The wrong value flashes and must be
corrected.
May occur when a feature is configured, but the dedicated input/
output is not configured. Usually this is solved by loading the default
input/output configuration (see the machine parameters).
This message is displayed when a bottoming sequence is
programmed, and bottoming is not allowed with either one of the
tools.
Axis manager error. The number gives more information. Most
common errors are described in messages E55 to E68.
If other error numbers are listed, please send conditions of
problem, traces and parameters to the Cybelec Technical support
for assistance.
Machine parameters incorrectly configured; the error page is
displayed.
All the back gauges programmed in Machine Parameters have none
selected for mode. Select at least one mode other than none.
When pressing start, the programmed amount of parts to be made
is ‘0’. See Number of parts for more information.
Cannot start cycle because repeat cycle function is set to “0”.