Upper Display Cable
NOTE: Display cables have a revision number label so that you can verify part number and
latest revision of the cable. The upper display cable part number is AW-17007.
Tools Required
3/16” Hex key
Phillips head screwdriver
ESD (Electro Static Discharge) grounding strap
Wire cutters
1. Disconnect the external power source.
A. Turn the main power switch above the power inlet to the off (O) position.
B. Unplug the power cord from the power outlet.
NOTE: Wear an ESD strap for the rest of this procedure.
2. Remove the top console back.
NOTE: If you have a cable plugged into the RJ-45 port disconnect it.
A. Using a Phillips head screwdriver, remove the five screws securing the top console
back to the console front.
B. Gently pull off the top console back. See Figure 24.
3. Remove the console.
A. Have a second person support the console until step 7A.
B. Using a hex key, remove the four screws and four lock washers securing the handrail
in place.
4. Remove the upper display cable.
A. Using a Phillips head screwdriver, loosen the wire retaining screw securing the display
cable in place near the display board. See Figure 30.
B. Disconnect the display cable (P3 and P8) from the upper display board. See Figure 27.
C. Disconnect the upper display cable from the lower display cable. See Figure 27.
D. Using wire cutters, cut the upper display cable in two and pull both ends out of the
unit. NOTE: Pull the upper end up and out and the lower end down and out.
5. Attach the new upper display cable.
A. Locate the end of the upper display cable with the single connector. See Figure 31.
Cybex Arc Trainer Owner’s & Service Manual