Charging System/Battery
15-1
15. Charging System/Battery
Service Information 15-1
Troubleshooting 15-2
Battery 15-3
Charging System Inspection 15-3
Regulator/Rectifier 15-5
A.C generator Inspection 15-6
Service Information
General Safety
● The maintenance-free (MF) battery does not require battery acid level inspection. Do not replenish distilled
water.
● To charge the battery, remove the battery from the frame, and charge it with its seal-cap closed.
● Unless required in an emergency, do not carry out battery quick-charging.
● Always charge battery based on the current and time specified on top of the battery.
● Use a tester to check the charging status (open voltage).
● Do not replace the battery with a general-type battery.
● Check the charging system in sequence based on troubleshooting table.
● Test-charging systems while they are mounted on the motorcycle.
● For information on generator disassembly, refer to section 8.
Item Standard values
Capacity 12V–8AH(MF)
Terminal-to-terminal voltage (When fully charged) 13.0–13.2V
Battery
Charging current 0.8A
Leakage current Not to exceed 1mA
Generator
Charging coil resistance value (20℃) 0.1~1.0Ω(20℃)
rpm at charging start 1,800rpm(night load)
Regulator/rectifier
Type Thyristor system
Regulator voltage 14.5±0.5V/5.000/rpm
Tools
Measuring instruments
Digital circuit tester
PVA Multi-tester.
Specifications