Page #166 background image
Maintenance Section
-164-
Every 2500 Service Hours or 15 Months
You must read and understand the warnings and instructions contained in the Safety section of this manual, before
performing any operation or maintenance procedures.
Hydraulic Oil - Check, Clean, Change
WARNING
Hot oil and components can cause personal injury.
Do not allow hot oil or components to contact skin.
Park the lift truck level with the forks lowered, mast tilted
back (all cylinders retracted), parking brake engaged,
transmission in NEUTRAL and the engine stopped.
1. Remove the hydraulic tank drain plug. Allow the oil
to drain. Clean and install the plug.
2. Raise the hood and seat assembly.
3. Remove dipstick/filter cap. Fill the hydraulic tank.
See “Refill Capacities.” Install the breather/dipstick.
4. Lower the hood and seat assembly.
5. Start the engine and operate the hydraulic controls,
and the steering system, through a few cycles to fill
the lines. Look for oil leaks.
6. Stop the engine and check the oil level. With all
cylinders retracted, maintain the oil level to the
FULL mark on the dipstick.