72
Unlock Responding
Interval
After unlock, the interval that the device responds to the next
unlock. The unit is “second”.
After unlock, the period that it remains unlocked. The unit is
“second”.
Check Door Sensor
Signal Before Lock
Tick “Check Door Sensor Signal Before Lock” to enable the
function. If door sensor signal exists, it will not be locked. However,
after opening time exceeds the door sensor check time, give door
sensor alarm and report the alarm info to management centre
automatically.
Support the following two ways:
Personal password: it can be set at VTH.
Unified password: after setting, every user
of the unit can unlock with this password.
This parameter
is displayed
after keyboard
module is
connected and
added to
façade layout.
New Unlock Password
Confirm
Tick “Menace Password Enable” to enable this
function.
In case of menace, input the menace password
to unlock; the device uploads the alarm info to
management center automatically.
New Menace
Password Confirm
Tick “Enable”. 2 pictures will be snapshot
automatically when the door is opened, and
uploaded to FTP.
1. Click “Issue Card”.
2. Swipe the unauthorized card at VTO.
Pop up “Card Info” interface.
3. Enter “Room No.” and “Card No.”, and click
“OK”.
Cards can be swiped continuously, within a
period of 30s.
4. Click “OK” to finish issuing card.
Click “OK” within the countdown, so the
cards will be valid. Otherwise, all card info
will be invalid.
Click “Cancel” when issuing cards, in order
to stop issuing.
This parameter
is displayed
after card
swiping module
is connected
and added to
façade layout.
Table 7-8
Click “OK” to save the settings. Step 3