5 Technical data
Service manual
114
EBLQ+EDLQ011~016CAV3+W1 + EBLQ+EDLQ011~016CA3V3+W1
+ EK(2)CB07CAV3 + EKMBUHCA3V3+9W1
Daikin Altherma – Monobloc
ESIE18-04 – 2019.02
English Translation
F1U Fuse T 5A 500V
F1U (A4P) Fuse T 2A 250V
F2B * Overcurrent fuse booster heater
F2U (A4P) Fuse T 2A 250V for 3-way valve
K1A Relay for heating
K1 * Terminal strip
K2A Relay for cooling
K2 * Booster heater
K3M * Contactor booster heater
M2P # Domestic hot water pump
M2S # Shut-off valve
M3S 3-way valve for domestic hot
water
M4S * Valve kit
PC (A7P) Power circuit
Q2L * Thermal protector booster heater
Q5DI, Q6DI Earth leakage circuit breaker
R1H (A3P) * Humidity sensor
R1T (A3P) * Ambient sensor On/OFF
thermostat
R1T (A5P) Ambient sensor user interface
R2T * External indoor floor/ambient
thermistor
R5T * Domestic hot water thermistor
S1S # Preferential kWh rate power
supply contact
STB * Thermal protector booster heater
X*A (A4P) Connector
X*M Terminal strip
*: Optional
#: Field supply
Control box option: backup heater
English Translation
BUH option Backup heater option
Control box Control box
Only for *** Only for ***
E1H Backup heater element (1kW)
E2H Backup heater element (2kW)
E3H Backup heater element
F1B * Overcurrent fuse backup heater
F1T, F2T * Thermal fuse backup heater
English Translation
F1U Fuse T 5A 500V backup heater
option
K1M * Contactor backup heater (step 1)
K1R * Relay backup heater (step 1)
K2M * Contactor backup heater (step 2)
(only for *9W)
K2R * Relay backup heater (step 2)
(only for *9W)
K5M * Safety contactor backup heater
(only for *9W)
Q1DI # Earth leakage circuit breaker
Q1L * Thermal protector backup heater
R2T * Outlet backup heater thermistor
X*M Terminal strip
*: Optional
#: Field supply
Control box option: option box
English Translation
Alarm output Alarm output
Control box Control box
Electric pulse meter inputs: 5 V
DC pulse detection (voltage
supplied by PCB)
Electric pulse meter inputs:
5VDC pulse detection (voltage
supplied by PCB)
Ext. heat source External heat source
External indoor ambient sensor
option
External indoor ambient sensor
option
Indoor Indoor
Max. load Maximum load
Max. voltage Maximum voltage
Min. load Minimum load
Option box Option box
ON ON
OFF OFF
A4P Extension PCB (control, optional)
DS1 (A4P) DIP switch
F1U (A4P) Fuse T 2A 250V
F2U (A4P) Fuse T 2A 250V for 3-way valve
R6T * External indoor ambient sensor
option
S5P-S6P # Electrical meters
X*A (A4P) Connector
X*M Terminal strip
*: Optional
#: Field supply