5 Technical data
Service manual
121
EBLQ+EDLQ011~016CAV3+W1 + EBLQ+EDLQ011~016CA3V3+W1
+ EK(2)CB07CAV3 + EKMBUHCA3V3+9W1
Daikin Altherma – Monobloc
ESIE18-04 – 2019.02
INFORMATION
The diagrams shown in this manual may be incorrect due
to changes/updates to the unit. Correct diagrams are
supplied with the unit and can also be found in the
technical data book.
X1M
%H20
R1H
DS1
ON
OFF
8 7 6 5 4 3 2 1
5
5
5
5
7
-t°
R1T
A5P
P1 P2
X1M/L
X1M/N
X1M/PE
7
A5P
P1 P2
-t°
R1T
A4P
F2U
F1U
+12V
GND
3
2
X2A
1
3
2
X14A
1
X1A
5
4
3
2
1
S1S
A2
A1
K3M
2
1
4
3
F2B
I I
2
1
E4H
1/3/31
2/4/32
Q2L
4
3
Y
L
N
M3S
5
67
X3A
8
4 3 2 1
R1T
-t°
R1T
-t°
R2T
-t°
R5T
- t°
Q5DI
L N
L N
X8M
6
7
PE
43
X11M
5 6
H
2 1
A7P
C
COM
L N
HC
COM
A3P
A3P
A3P
PC
Q6DI
1
X8M
2
3
4
5
X4M/X7M
1 2
X6M
1 2
X4A
1
2 3 4 5 6
20
X2M
21
X10A
2
1
X1M
L
N
1
X5A
2
3
34
11
13
X2M
14
15
12
X2M
X2M
7
8 9
5
X2M
6
10
22
X2M
23
INDOOR
M2P
M
1~
89
F1U
10
L
Y
N
M4S
1
5
K1A
1
5
K2A
4
3
4
3
M2S
K2
STB
L1
K1
N
X2M
1a
1
2
3
X2M.1
X2M.1a
X2M.1a
X2M.2
X2M.1
X8M.4
X8M.6
X8M.7
X2M.2
X2M.1
X2M.2
X2M.1
X8M.5
X2M.1a
X5M/3
X5M/4
X5M/2
X5M/1
X3M/4
X3M/3
X3M/2
X3M/1
R5T / X2M.3
R5T / X2M.4
R5T / X2M.4
R5T/ X2M.3
X2M.1
X2M.2
X2M.1a
A4P/X5A.2
A4P/X5A.1
A4P/X5A.3
X2M.2
X15M/3
X15M/4
X15M/5
X15M/6
X15M/7
X15M/1
X15M/2
X5Y
X8M.5
X8M.4
X8M.6
X8M.7
OUTDOOR
INDOOR
Hydro switch box
Control box
Option box
Option box
DHW pump output
Max. load:
2 A (inrush) - 230 V AC
1 A (continuous)
Heatpump convector
NO valve
only for wireless On/OFF thermostat
only for ext. sensor
Dual setpoint application
(refer to installation manual)
only for wired On/OFF thermostat
1N~, 50 Hz
230 V AC
1N~, 50 Hz
230 V AC
Only for *KHWP*/*HYC*/*KHWS*V3
Preferential kWh
rate power supply
contact:
5V DC detection
(voltage supplied
by PCB)
Only for *KHWP*/*HYC*
domestic hot water tankdomestic hot water tank
Only for *KHWS*V3
DHW option
BUH option
Remote user
interface
User interface
DHW pump
4D115042
INFORMATION
The diagrams shown in this manual may be incorrect due
to changes/updates to the unit. Correct diagrams are
supplied with the unit and can also be found in the
technical data book.
K5M
K1M
K2M
2
3 3
2
2
3
4
3
2
1
F1T
F1T
F1T
E1H
E1H
E1H
F2T F2T
F2T
E2H
E2H
E2H
R2T
- t°
PE
1
X15M
2
Q1DI
4
3
6
5
2
1
4
3
6
5
2
1
6
5
14
13
2
1
4
3
6
5
8
7
F1B
II I I
L1 L2 L3 N
5 6
X14M
1
2 3 4
F1T
F1T
F1T
E1H
E1H
E1H
F2T F2T
F2T
E2H
E2H
E2H
5 6
41
X14M
3
X15M
4
5
6
7
1
5
K1R
1
5
K2R
31
32
Q1L
11
12
A1
A2
K5M
3
4
3
4
A1
A2
K1M
A1
A2
K2M
4
3
2
1
PE
Q1DI
4
3
6
5
2
1
4
3
6
5
2
1
6
5
14
13
2
1
4
3
6
5
8
7
F1B
II I I
L N
R2T
- t°
1
X15M
2
3
X15M
4
5
6
7
1
5
K1R
31
32
Q1L
A1
A2
K1M
4
3
2
1
F1T
Q1DI
E3H
2
1
4
3
F1B
I I
21
22
L
N
3
4
11
12
F1U
F1U
X2M/11
X2M/12
X2M/13
X2M/14
X2M/15
X2M/5
X2M/6
Control box
1N~, 50 Hz
230 V AC
)W9*( noitpo HUB)V3* rof ylno( noitpo HUB
Wk 6 ro Wk 3 , V 032 , ~N1Wk 9 ro Wk 6 V 004 ~ N3
4D115042