2 Components
Service manual
68
EBLQ+EDLQ011~016CAV3+W1 + EBLQ+EDLQ011~016CA3V3+W1
+ EK(2)CB07CAV3 + EKMBUHCA3V3+9W1
Daikin Altherma – Monobloc
ESIE18-04 – 2019.02
a Latch
b Wire terminal mounting plate
c Wire terminal LB
d Wire terminal NB
e Faston connector with orange wire (+)
f Faston connector with grey wire (-)
g Tie strap
h Red and blue wiring
i Cable guide
j Compressor wiring
k Connector X205A
l Connector X9A
3 Turn over the wire terminal mounting plate.
4 Disconnect the wire terminals LB and NB from the main PCB.
5 Disconnect the 2 Faston connectors.
6 Cut the tie 2 straps.
7 Remove the red and blue wiring from the cable guides.
8 Remove the compressor wiring from the cable guides.
9 Disconnect the connectors X205A and X9A.
10 Insert 2 flathead screwdrivers in the slots and unlatch the upper
and lower assemblies.
a Slot
b Upper assembly
c Lower assembly
11 Slightly lift the upper assembly and slide it to the right to release
the 3 hooks.